New from 1 March and 1 July 2027
Victoria's rental energy efficiency standards: what changes in 2027
Six energy efficiency standards join Victoria's rental minimum standards in 2027: five from 1 March and one from 1 July. This guide sets out what each one requires, which rental agreements it applies to, and how to check a property against them before the dates arrive.
Key dates at a glance
- 1 March 2027: showerheads, heating, cooling, hot water and ceiling insulation.
- 1 July 2027: draughtproofing.
- 1 July 2030: the cooling standard extends to every rental property.
The six standards at a glance
| Standard | Starts | Applies to | In short |
|---|---|---|---|
| Showerheads | 1 Mar 2027 | Agreements entered into from that date | 4-star shower head, or 3-star where the plumbing can't take one |
| Heating | 1 Mar 2027 | All rental properties | Energy-efficient fixed electric heater in the main living area, with allowances for existing heaters |
| Cooling | 1 Mar 2027 | Agreements entered into from that date; every rental from 1 Jul 2030 | Energy-efficient fixed cooler in the main living area |
| Hot water | 1 Mar 2027 | All rental properties | Heat pump or solar water heater. A working heater installed before the date still meets it |
| Ceiling insulation | 1 Mar 2027 | Agreements entered into from that date | Whole ceiling insulated. Existing insulation counts; bare areas need R5.0 |
| Draughtproofing | 1 Jul 2027 | Agreements entered into from that date | External doors and windows weather-sealed, wall vents sealed |
Which rental agreements do they apply to?
Two of the standards, heating and hot water, apply to all rental properties from 1 March 2027. The other four apply to a rental agreement entered into or created on or after the start date. That includes a fixed-term agreement that converts to month-to-month from that date. An agreement signed before the date is an earlier agreement, even if the tenancy starts after it.
In practice that means the new standards reach most properties at the next new agreement or rollover, which is why it's worth knowing where each property stands well before then.
Check a property against these standards today
Switch on Upcoming standards when you set up a Minimum Standards inspection. The new checks are marked with their start date and reported separately from the current 15.
1. Showerheads
For a rental agreement entered into or created on or after 1 March 2027, every shower must have a shower head with a 4-star water efficiency (WELS) rating. A 3-star rating is acceptable if a 4-star shower head cannot be installed, or will not work effectively, because of the age, nature or structure of the plumbing. Earlier agreements stay on the current 3-star standard.
- 4-star WELS shower head on every shower
- 3-star accepted where the plumbing can't take a 4-star head
- Agreements made before 1 March 2027 stay on the 3-star standard
2. Heating
Every rental property must already have a fixed heater (not a portable one) in good working order in, or with an outlet in, the main living area. From 1 March 2027 that heater must be an energy-efficient electric heater: a non-ducted air conditioner or heat pump with a 2-star or higher heating rating, or a ducted system with a Heating Seasonal Performance Factor of 3.2 or more.
Any fixed heater in good working order still meets the standard where an energy-efficient one is unreasonable. Examples include a heater installed before 1 March 2027 that is a 2-star or higher non-ducted air conditioner, heat pump or gas space heater, a ducted or hydronic system, a wood heater or an LPG heater; a like-for-like wood or LPG replacement; a replacement under warranty; owners corporation rules; a refused heritage permit; or a cost well above the average.
- Fixed heater in, or with an outlet in, the main living area
- Heater in good working order
- Energy-efficient electric model, unless one of the allowances applies
3. Cooling
For a rental agreement entered into or created on or after 1 March 2027, the property must have a fixed cooler (not a portable one) in good working order in, or with an outlet in, the main living area. From 1 July 2030 this applies to every rental property.
The cooler must be energy efficient: a non-ducted electric air conditioner or heat pump with a 3-star or higher cooling rating, or a ducted system with a Total Cooling Seasonal Performance Factor of 3.8 or more. Any fixed cooler in good working order still meets the standard where an energy-efficient one is unreasonable, for example where a fixed cooler (including ducted evaporative cooling) was installed before 1 March 2027 and is in good working order.
- Fixed cooler in, or with an outlet in, the main living area
- Cooler in good working order
- Energy-efficient model, unless an existing fixed cooler qualifies
4. Hot water
From 1 March 2027, a rental property must have an energy-efficient water heater supplying hot water to the kitchen, laundry and bathroom: an electric heat pump or a solar water heater that meets the Plumbing Code minimums.
A water heater installed before 1 March 2027 that is in good working order and supplies all three meets the standard, so the new requirement applies when the existing system fails and cannot be repaired. It also does not apply where it is unreasonable, for example where hot water comes from a centralised system (common in apartment buildings), for a like-for-like LPG or warranty replacement, under owners corporation rules, or where a heritage permit was refused.
- Hot water supplied to the kitchen, laundry and bathroom
- Existing heater in good working order, or a heat pump or solar replacement
5. Ceiling insulation
For a rental agreement entered into or created on or after 1 March 2027, the whole ceiling must be insulated. Ceiling areas that already have insulation batts, blankets, rigid boards or loose fill of any R-value meet the standard; foil on its own does not. Areas with none need insulation with a minimum R-value of 5.0, installed by a qualified installer after a licensed or registered electrician has completed the pre-insulation electrical safety checklist.
The standard does not apply to internal ceilings (for example below another storey or apartment), to external parts such as garages and outbuildings, or to areas where installing insulation is unreasonable or unsafe, for example where it cannot be installed without substantial building work (as with some skillion or very low-pitched roofs) or where the roof cavity is common property.
- Insulation present across the whole ceiling
- Uninsulated areas brought up to at least R5.0
- Foil alone does not count
6. Draughtproofing
For a rental agreement entered into or created on or after 1 July 2027, external doors and windows must be fitted with sealing or weather-stripping around their entire perimeter, without affecting how they open and close, and unsealed wall vents must be sealed or closed. A property with no wall vents meets that part of the standard. Non-fixed products such as door snakes do not meet the standard.
The standard does not apply where a flueless space heater or an open-flued gas appliance is installed anywhere in the property (in a kitchen, also a flueless gas cooker without a rangehood), where owners corporation rules in an apartment building prohibit sealing external doors, where a heritage permit was refused, or where it is otherwise unreasonable. If the property has gas appliances, a gas safety check less than six months old is needed before draughtproofing work is done.
- Every external door sealed around its whole perimeter
- Every external window sealed around its whole perimeter
- Unsealed wall vents sealed or closed
How to get ready
- Find the gaps now. Walk the property against the six standards while there is still time to plan. Most fixes need a trade, and trades get busy as a deadline approaches.
- Record what's already there. Photograph the heater, cooler and water heater with their rating labels, and the ceiling insulation where you can sight it. Whether an appliance was installed before 1 March 2027 matters for several of the standards.
- Sequence the work. Insulation needs an electrician's pre-insulation safety checklist first. Draughtproofing needs a recent gas safety check if the property has gas appliances.
- Keep the report. A dated report with photos shows what was assessed and when, and gives the rental provider a clear list to act on.
In the Minimum Standards Checklist app, the 2027 checks are optional until each start date. Switch them on at setup and they appear in the checklist with a "From 1 Mar 2027" or "From 1 Jul 2027" marker, then print in their own block of the PDF, outside the report totals. From each start date they become part of every inspection dated on or after it.
Who the standards don't cover
Community housing and specialised housing programs come under a separate schedule of the regulations, which does not include the 2027 energy efficiency standards. Rooming houses have their own minimum standards. This guide covers general residential rental properties.
Frequently asked questions
When do Victoria's rental energy efficiency standards start?
Five standards start on 1 March 2027: showerheads, heating, cooling, hot water and ceiling insulation. Draughtproofing starts on 1 July 2027. From 1 July 2030 the cooling standard extends to every rental property.
Do the 2027 standards apply to existing rental agreements?
It depends on the standard. Heating and hot water apply to all rental properties from 1 March 2027. Showerheads, cooling, ceiling insulation and draughtproofing apply to rental agreements entered into or created on or after their start date, which includes a fixed-term agreement that converts to month-to-month from that date. An agreement signed before the date is an earlier agreement, even if the tenancy starts after it.
Does every rental need new insulation, a new heater or a new hot water system by 1 March 2027?
Not necessarily. Ceiling areas that already have insulation batts, blankets, rigid boards or loose fill of any R-value meet the insulation standard. A water heater installed before 1 March 2027 that is in good working order meets the hot water standard until it fails and cannot be repaired. Many existing fixed heaters and coolers in good working order also continue to meet the standard. Each standard has its own conditions and exemptions, so check them against the property.
Can I check a property against the 2027 standards before they start?
Yes. The Minimum Standards Checklist app has both sets of 2027 standards built in. Switch on Upcoming standards when you set up a Minimum Standards inspection and the new checks are added to the checklist, marked with their start date and reported separately from the current standards. It is optional and off by default.
Related guides
- All 15 rental minimum standards, explained
- Free printable minimum standards checklist (PDF)
- Electrical safety checks for Victorian rentals
- Smoke alarm requirements for Victorian rentals
This guide is general information, not legal advice. It summarises the Residential Tenancies Amendment (Minimum Energy Efficiency Standards) Regulations 2025 and guidance published by Consumer Affairs Victoria. Exemptions apply and dates can change, so always check the official sources for the requirements that apply to your property.