Every rental agreement from 13 October 2026
Electrical safety checks for Victorian rental properties
Victorian rental properties must have an electrical safety check at least once every 2 years, carried out by a licensed or registered electrician. The requirement currently applies to rental agreements entered into on or after 29 March 2021 — and from 13 October 2026 it extends to every rental agreement, no matter when it started. Here's what rental providers, property managers and electricians need to know.
When a check is required
- At least every 2 years. An electrical safety check of the property must be conducted at least once every 2 years by a licensed or registered electrician.
- Agreements from 29 March 2021. The two-yearly check is currently mandatory for rental agreements entered into on or after 29 March 2021, including fixed-term agreements that have rolled over to periodic since that date.
- All agreements from 13 October 2026. From 13 October 2026, the two-yearly gas and electrical safety checks apply to every Victorian rental agreement, whether it started before, on or after that date.
- Catch-up on move-in. If no electrical safety check has been conducted in the 2 years before a renter moves in, one must be arranged as soon as possible.
Who can carry one out
Only a licensed or registered electrician can conduct an electrical safety check on a rental property. Rental providers can verify a licence or registration on the electrician's card or through Energy Safe Victoria. The safety check record must include the electrician's licence or registration number — a report without it doesn't stand up as a compliance record.
What the check covers
The check covers all electrical installations, fixtures and fittings provided by the rental provider, conducted in accordance with section 4 of AS/NZS 3019 (periodic verification of electrical installations). A thorough check works through:
- Scope of the inspection — which parts of the installation were covered, and any limitations such as areas with no access on the day
- Visual assessment — consumer mains, switchboard condition and circuit labelling, earthing, socket outlets, light fittings, fixed appliances, visible wiring, and solar, pool or EV equipment where fitted
- Polarity and connection testing — correct polarity and secure connections at the switchboard, socket outlets, lighting circuits and fixed appliance connections
- Earth continuity testing — the main earthing conductor, water piping bond, and earths at outlets and Class I appliances
- Safety switch (RCD) testing — every RCD push-button tested, with trip-time measurements against the limits in AS/NZS 3019
- Observations and recommendations — anything found, any repairs required, and the actions taken to address them, recorded in writing
Energy Safe Victoria publishes a standard electrical safety check report template for electricians, and a written report against it — dated, signed and retained — is what turns the visit into a compliance record.
Record-keeping and disclosure
- Keep the record. The rental provider must keep a record of the most recent electrical safety check until a record of the next check is created.
- Provide it within 7 days. If the renter asks in writing, the rental provider must give them the record of the most recent check within 7 days.
- Disclose before the agreement. Before a rental agreement starts, the provider must disclose the date of the last electrical safety check and any outstanding recommendations.
- Act on faults. A dangerous electrical fault is an urgent repair under Victorian rental law. If the provider doesn't act, the renter can authorise urgent repairs up to $2,500 and seek reimbursement.
Safety check vs the electrical safety minimum standard
These are two separate obligations that are easy to conflate:
- The electrical safety minimum standard requires the property to have a modern switchboard with circuit breakers and safety switches (RCDs) — a condition the property itself must meet.
- The electrical safety check is the recurring two-yearly inspection of the whole electrical installation by a licensed or registered electrician.
A property needs to satisfy both — and both are worth documenting with a dated, signed report.
Finish the report before you leave the driveway
The app walks licensed or registered electricians through the full check — visual, polarity, earth continuity and RCD tests — then generates a certified, branded PDF ready to email on the spot.
Frequently asked questions
How often does a Victorian rental property need an electrical safety check?
At least once every 2 years. The requirement currently applies to rental agreements entered into on or after 29 March 2021, and from 13 October 2026 it extends to every Victorian rental agreement, no matter when it started. If no check has been done in the 2 years before a renter moves in, one must be arranged as soon as possible.
Who can carry out an electrical safety check on a rental property?
Only a licensed or registered electrician. Rental providers can verify a licence or registration on the electrician's card or through Energy Safe Victoria. The safety check record must include the electrician's licence or registration number.
What does an electrical safety check cover?
All electrical installations, fixtures and fittings provided by the rental provider, checked in accordance with section 4 of AS/NZS 3019. In practice that means a visual assessment of the installation, polarity and connection testing, earth continuity testing, and testing of every safety switch (RCD), with the findings, observations and recommendations recorded in a written report.
Is the electrical safety check the same as the electrical safety minimum standard?
No. The electrical safety minimum standard requires the property to have a modern switchboard with circuit breakers and safety switches (RCDs) — a one-off condition the property must meet. The electrical safety check is a recurring two-yearly inspection of the whole electrical installation by a licensed or registered electrician. A property needs to satisfy both.
What records of an electrical safety check must be kept?
The rental provider must keep a record of the most recent electrical safety check until the next check's record is created, and give the renter a copy within 7 days of a written request. Before a rental agreement starts, the provider must also disclose the date of the last check and any outstanding recommendations.
Related guides
- The 2027 rental energy efficiency standards, explained
- All 15 rental minimum standards, explained
- Smoke alarm requirements for Victorian rentals
- Free printable minimum standards checklist (PDF)
This guide is general information, not legal advice. It summarises electrical safety check guidance published by Consumer Affairs Victoria and Energy Safe Victoria — always check the official pages for the current requirements.